000 02796ntm a2200289 a 4500
001 vtls000084606
003 KUKTEM
005 20251117113249.0
008 141222t2014 my a f m 000 0 eng d
020 _aTHE0004169(Local)
039 9 _a201905141718
_bfarhana
_c201712051553
_dhuda
_y201412221157
_zfawwaz
040 _aUMP
090 _aTP156.O7 A84 2014 r Bc.
100 0 _aNur Athirah Sabarudin
245 1 0 _aPurification of sorbitol using reverse osmosis membrane :
_beffect of cross flow velocity and transmembrane pressure /
_cNur Athirah Sabarudin
260 _aKuantan, Pahang :
_bUMP,
_c2014
300 _axvi, 73 p. :
_bill. ;
_c30 cm. +
_e1 CD-ROM
500 _aFaculty of Chemical & Natural Resources Engineering
502 _aProject paper (Bachelor of Chemical Engineering (Biotechnology)) -- Universiti Malaysia Pahang - 2014
504 _aBibliography : p. 65-68
520 3 _aSorbitol, a sugar alcohol that has formula of C6H14O6 also known as D-Glucitol. It can be obtained from the reduction of glucose, by changing the aldehyde group to hydroxyl group. It is very slow to metabolize in body, which lessen the chance of increasing the level of insulin, thus makes sorbitol is a good sweetener for diabetics. Since the use of sorbitol in the food industry more widely, sorbitol purity is a key factor before it is used as an additive in food. One of the method to purify sorbitol is application of membrane technology. However the membrane application is limited due tochallenges such as decay in permeate flux and increases the complexity of membrane operations. Thus, this research was conducted to study the effect of cross flow velocity (CFV) and transmembrane pressure (TMP) on the flux in purification of sorbitol using the reverse osmosis membrane. The flux was determined from the calculated of permeate flow rate divide by the area of spiral wound membrane. In order to study the optimize condition for the process, the value of TMP and CFV was varied to obtained the flux value. While varying the CFV value, the TMP value was constant and when the TMP was varied, the CFV was constant. This study was conducted for 60 minutes, and every 10 minutes the permeate flow rate was collected to get the flux value. The solution was prepared with constant concentration of 10g/L in a 100 L solution in tank. The determination of sorbitol was analyze by refractometer. Based on the result obtained, increasing in CFV and TMP give the highest flux value
650 0 _aReverse osmosis
650 0 _aWater
_xPurification
_xReverse osmosis process
650 0 _aMembranes (Technology)
856 4 0 _uhttp://ecollib.ump.edu.my/9810/
_zAccess in library only
999 _aVIRTUA40
_c5703
_d5709
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6500*6501*6502*8560*9992