000 02723ntm a2200289 a 4500
001 vtls000092081
003 KUKTEM
005 20251117113256.0
008 151117t2015 my da f abm 000 0 eng d
020 _aTHE0000731(Local)
039 9 _a201905161601
_bnazirah
_c201711301542
_dfateeha
_y201511171624
_zasma
040 _aUMP
090 _aFKASA .T36 2015 r Bc.
100 1 _aTan, Yeong Yu
245 1 4 _aThe performance of closed loop steel fiber concrete /
_cTan Yeong Yu
260 _aKuantan, Pahang :
_bUMP,
_c2015
300 _axv, 92 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 CD ROM
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015
504 _aBibliography : p. 84-92
520 3 _aThis paper discusses the performance of the steel fiber concrete. When the straight fibers are introduced to the concrete mix, the direction of the steel fibers can be affected by the mould, balling together and random orientation. As the result smaller percentage of the steel fibers are being applicable when compared to the original designed. The closed loop steel fibers technology is to overcome the problem face by straight steel fibers, this is because closed loop fibers design to place the fibers in position where it able to interlock with the aggregate during the concrete mix. There are several test being analysis during this research which is compressive test, flexural test, water absorption test, porosity and segregation test. The different type of test method had been carry out is to determine the performance of the closed loop steel fiber and existing hooked end steel fibers. By adding the closed loop steel fiber, the compressive strength is 32 % from the plain concrete. In addition, the flexural strength is 30 % higher compare to the plain concrete. By using the closed loop steel fiber manage to overcome the segregation by the steel able to interlock with the aggregate instead of passing through it. Concrete cubes and beams were manufactured with a fixed addition of fibers by weight. The outcomes showed an improvement in the performance of the closed loop steel fiber when compared to the hooked end steel fibers. This finding is essential because closed loop steel fibers are not commercially available at the present period
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and Colleges
_xDissertations
650 0 _aTheses
856 4 0 _uhttp://ecollib.ump.edu.my/id/eprint/25097
_zAccess in library only
999 _aVIRTUA40
_c5940
_d5946
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6100*6500*6501*8560*9992