| 000 | 02763ntm a2200289 a 4500 | ||
|---|---|---|---|
| 001 | vtls000092237 | ||
| 003 | KUKTEM | ||
| 005 | 20251117113258.0 | ||
| 008 | 151124t2015 my ao f aosm 000 0 eng d | ||
| 020 | _aTHE0000494(Local) | ||
| 039 | 9 |
_a201905151530 _bnazirah _c201711281657 _dsaini _c201512011028 _dasma _c201511251426 _dtraining1 _y201511241619 _ztraining1 |
|
| 040 | _aUMP | ||
| 090 | _aFKASA .I993 2015 r Bc. | ||
| 100 | 0 | _aIzzatulhanis Rosli | |
| 245 | 1 | 0 |
_aAdverse effect of antropogenic activities on water quality of the Pekan River / _cIzzatulhanis Rosli |
| 260 |
_aKuantan, Pahang : _bUMP, _c2015 |
||
| 300 |
_axiii, 56 p. : _bill. (some col.) ; _c30 cm. + _e1 CD ROM |
||
| 500 | _aFaculty of Civil Engineering and Earth Resources | ||
| 502 | _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015 | ||
| 504 | _aBibliography : p. 43 | ||
| 520 | 3 | _aA study on anthropogenic activities and water quality was carried out in the Pekan river, taking into account the location of the river which is at the centre of the Pekan city. The objectives of the study were to evaluate the water quality based on National Water Quality Standard (NWQS) and Water Quality Index (WQI) Malaysia of surface water quality in the Pekan river, and to identify the sources of pollution for sustainable management in the Pekan river. Three stations have been chosen to be tested its surface water condition. Station 1 was at the upper stream, and Station 3 on the downstream. Data of six in-situ parameters were collected; dissolved oxygen (DO), temperature, pH, electrical conductivity (EC), turbidity and salinity. The other parameters such as total suspended solids (TSS), Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Ammoniacal Nitrogen (AN), Sulphate, Phosphate and Heavy metals were test in laboratory. The results showed that BOD value was higher on Station 1 (11.02 mg/l) compared to other stations. The BOD value of the Pekan river was higher than the NWQS threshold level. The highest TSS value was at Station 3 (77.75 mg/l). Turbidity on Station 3 was higher (272.5 NTU). Overall, Pekan river was categorized as Class III based on WQI Malaysia, meaning the water cannot be used without proper treatment. The authorities should take action in controlling the condition of the river and establish the awareness of importance of river water among the community | |
| 610 | 2 | 0 |
_aFaculty of Civil Engineering and Earth Resources _xDissertations |
| 650 | 0 |
_aUniversities and Colleges _xDissertations |
|
| 650 | 0 | _aTheses | |
| 856 | 4 | 0 |
_uhttp://ecollib.ump.edu.my/id/eprint/9529 _zAccess in library only |
| 999 |
_aVIRTUA40 _c5997 _d6003 |
||
| 999 | _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6100*6500*6501*8560*9992 | ||