000 03241ntm a2200289 a 4500
001 vtls000092192
003 KUKTEM
005 20251117113301.0
008 151123t2015 my da f abm 000 0 eng d
020 _aTHE0000769(Local)
039 9 _a201905161456
_bnazirah
_c201712081128
_dnazri
_y201511231114
_zasma
040 _aUMP
090 _aFKASA .T66 2015 r Bc.
100 1 _aTong, Foo Sheng
245 1 0 _aShear strengthening of RC deep beams with large openings using carbon fiber reinforced polymers (CFRP) /
_cTong Foo Sheng
260 _aKuantan, Pahang :
_bUMP,
_c2015
300 _axvi, 88 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 CD ROM
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015
504 _aBibliography : p. 76-80
520 3 _aThis research deals with the experimental study of the behaviour of reinforced concrete deep beams with or without large rectangular openings as well as openings strengthened using externally bonded Carbon Fiber Reinforced Polymer (CFRP) composites in shear. The structural behaviour, including the load deflection, cracking patterns, failure mode, and effectiveness of the CFRP wraps were investigated. A total of four (4) specimens of beams with compressive strength of 35 MPa were tested to induce shear failure under 4 points loading test, which included one solid deep beam acted as a control beam (CB), one of which was tested without strengthening (US-BRO), and the remaining beams were strengthened with CFRP wraps in varying configurations around the opening (S-BRO-1, S-BRO-2). The beam had a cross section of 120 mm in width and 600 mm in depth as well as a length of 2400 mm. All the test specimens had a same geometry, main reinforcement arrangements and openings location. All the preparatory works of specimen materials were conducted in Laboratory FKASA. The examined parameter was the effect of configurations of the CFRP wraps used for the shear strengthening. The inclusion of un-strengthened large rectangular openings in the shear zone of a reinforced concrete deep beam leads to a reduction of ultimate beam strength by approximately 70%. The application of CFRP wraps with the presented strengthening configurations restricted the propagation of the diagonal crack and effectively increases ultimate load-carrying capacity as well as the ductility of the beam. The strength re-gains by U-shaped strengthening configuration around the openings was approximately 36% as compared to the beam with un-strengthened openings. However, the deep beam with U-shaped CFRP with horizontal fiber strengthened at the top and bottom chords of the openings were not capable to restore the control beam’s original structural strength remarkably. The beam only managed to re-gain about 41% of the control beam’s capacity
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and Colleges
_xDissertations
650 0 _aTheses
856 4 0 _uhttp://ecollib.ump.edu.my/25677/
_zAccess in library only
999 _aVIRTUA40
_c6071
_d6077
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6100*6500*6501*8560*9992