000 02807ntm a2200289 a 4500
001 vtls000092140
003 KUKTEM
005 20251117113310.0
008 151119t2015 my da f abm 000 0 eng d
020 _aTHE0000358(Local)
039 9 _a201905141734
_bnazirah
_c201711281540
_dfateeha
_y201511191458
_zasma
040 _aUMP
090 _aFKASA .C46 2015 r Bc.
100 1 _aChong, Wen Khai
245 1 0 _aExperimental study on the behaviour of reinforced concrete deep beams with large circular openings strengthened using CFRP /
_cChong Wen Khai
260 _aKuantan, Pahang :
_bUMP,
_c2015
300 _axvii, 74 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 CD ROM
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015
504 _aBibliography : p. 68-69
520 3 _aThis experimental research was conducted to study the behaviour of unstrengthen RC deep beams with openings and strengthened using Carbon Fiber Reinforced Polymer (CFRP). Strengthening configuration of CFRP-wrap used in this study were U-wrap and surface-wrap which applied with one layer of CFRP and in vertical alignment (90o). Four RC deep beams which included a solid control beam, a beam with two large circular openings, beams with two large circular openings strengthened using U-wrap and surface-wrap were tested to failure under four-point loading. All the beam specimens were in a dimension of 120 x 600 mm and 2400 mm in length. The support and loading point were located at 300 mm and 800 mm from the edge of the RC deep beams, respectively. Circular openings was designed with a standard of 0.45h which considered as large circular openings in a diameter of 270 mm that located 435 mm from the edge of the RC deep beams. Shear span-to-depth ratio (a/h) in this study was 0.83 in which the distance between the loading point and the support was 500 mm in order for the beam specimens to fail in shear region. RC deep beam with large circular openings, NS-BCO greatly reduced the beam strength, approximately 51.20 % as compared to the control beam. On the other hand, RC deep beam with circular openings strengthened using U-wrap, UW-BCO increases the beam strength up to almost 85.0 % as compared to NS-BCO. Hence, the most effective strengthening method was U-wrap, UW-BCO which re-gained the beam strength up to 90.28 % as compared to control beam
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and Colleges
_xDissertations
650 0 _aTheses
856 4 0 _uhttp://ecollib.ump.edu.my/id/eprint/25621
_zAccess in library only
999 _aVIRTUA40
_c6316
_d6322
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6100*6500*6501*8560*9992