000 02831ntm a2200265 a 4500
001 vtls000091270
003 KUKTEM
005 20251117113310.0
008 150921t2015 my a f m 000 0 eng d
020 _aTHE0002145(Local)
039 9 _a201905131658
_byusri
_c201711281649
_dsaini
_y201509211308
_zhuda
040 _aUMP
090 _aQD341.H9 C46 2015 r Bc.
100 1 _aChong, Soo Ling
245 1 0 _aFabrication of glucose sensor using graphene /
_cChong Soo Ling
260 _aKuantan, Pahang :
_bUMP,
_c2015
300 _axiv, 37 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 CD ROM
500 _aFaculty of Chemical & Natural Resources Engineering
502 _aProject paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2015
504 _aBibliography : p. 31-33
520 3 _aGraphene is a one-atom-thick allotrope of carbon. Due to its unique mechanical and electronic properties, graphene has been touted as very promising material for a great number of applications. In particular, biosensor is a device for the detection of specific analyte which combines a biological compound with a physicochemical detector component. There are three major components that complete a biosensor, namely the sensitive biological element, the transducer or detector element and also the associated electronics or signal processors. The working principle of graphene-based enzymatic electrodes is based on the direct electrochemistry of enzymes whereby electron transfer occurs between the electrode and the active centre of the enzymes without the participation of any mediators or reagents. In the current work, a graphene based glucose biosensor was prepared. The reduced graphene oxide (RGO)-glucose oxidase (GOx) was prepared from graphite powder as starting material. Material synthesis involved pre-oxidation of graphite to graphite oxide followed by further oxidation to graphene oxide. Subsequently, hydrazine monohydrate was used to reduce the graphene oxide to reduced graphene oxide. Finally, glassy carbon electrode (GCE) /RGO-GOx based glucose sensor was fabricated. Thereafter, the sample was tested with different concentrations of glucose solution. It was also being subjected to ultraviolet-visible absorption spectrophotometry (UV-Vis), Fourier transform infrared spectroscopy (FTIR) and cyclic voltammetry (CV). From this study, the obtained results are allowed for assessment of an optimum and sensitivity of the GCE/RGO-GOx based glucose biosensor towards the glucose concentration. It can be concluded that GCE/RGO-GOx based glucose biosensor can detect circa 3 to 7 mM glucose.
650 0 _aGraphene
856 4 0 _uhttp://ecollib.ump.edu.my/id/eprint/25285
_zAccess in library only
999 _aVIRTUA40
_c6325
_d6331
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6500*8560*9992