000 03036ntm a2200277 a 4500
001 vtls000102672
003 KUKTEM
005 20251117113342.0
008 180105t2017 my a f a m 000 0 eng d
020 _aTHE0000360(Local)
039 9 _a201905141735
_bnazirah
_y201801050935
_zfateeha
040 _aUMP
090 _aFKASA .C48 2017 r Bc.
100 1 _aChua, Zhen Yang
245 1 2 _aA study on spent coffee ground as cement admixtures /
_cChua Zhen Yang
260 _aKuantan, Pahang :
_bUMP,
_c2017
300 _axi, 61 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 CD ROM
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2017
504 _aBibliography : p. 45-49
520 3 _aThe purpose of carrying out this research is to find out the properties of spent coffee ground and its effect as cement retarding admixtures. The research started with using 0%, 0.2%, 0.4%, 0.6%, 0.8% and 1.0% of SCG being added into mortar mix as retarding admixtures. The proportion of sand to cement to water used in mortar mix design for this research is 2.75: 1: 0.6 according to the standard ASTM C1329-05. Fresh and hardened properties tests were carried out for this mortar mix, namely the flow table test, Vicat test and compressive strength test by using size 50mm x 50mm x 50mm cube. The mortar cubes were cured for 3, 7, 28 and 45 days. X-Ray Diffraction (XRD), X-Ray Florescence (XRF) and SEM EDX were also conducted in order to determine the chemical composition of the spent coffee ground and the microstructure of the mortar after the addition of spent coffee ground as retarding admixtures. The result of the flow table test shows the mortar maintain its flow ability within the standard values after the addition of SCG at various percentage. Moreover, the Vicat test of the SCG mortar shows that the mortar paste containing 0.6 % of SCG and above has retard the initial and final setting time of the mortar. In addition, the compressive strength test recorded that the compressive strength of 0.6 SCG mortar is highest compared to all other SCG mortar and also higher than the control mortar. The 0.6 SCG mortar compressive strength is recorded at 42.857 MPa whereas the control mortar is at 37.345 MPa, 14.76% higher than the control mortar. The XRD and XRF tests show that the major component in SCG are Potassium Oxide, Potassium Sodium Calcium Aluminium Chromium Oxide Silicate, and Tschortnerite. Indeed, the peak of SCG is at 20.20 and it is also found to highly content native cellulose or hemi cellulose. The higher number of C-S-H bond also observed in 0.6 SCG mortar compared to the control mortar, which results in higher compressive strength.
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and Colleges
_xDissertations
650 0 _aTheses
999 _aVIRTUA40
_c7218
_d7224
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6100*6500*6501*9992