| 000 | 02736ntm a2200373 i 4500 | ||
|---|---|---|---|
| 001 | vtls000102934 | ||
| 003 | KUKTEM | ||
| 005 | 20251117113350.0 | ||
| 008 | 180207s2017 my a f am 000 0 eng d | ||
| 020 | _aTHE0001023(Local) | ||
| 039 | 9 |
_a201905241054 _bnazirah _c201802201109 _dsaini _c201802071102 _dsaini _c201802071101 _dsaini _y201802071048 _zsaini |
|
| 040 |
_aUMP _beng _cUMP _erda |
||
| 090 | _aFKKSA .S933 2017 r Bc. | ||
| 100 | 0 |
_aMuhammad Syazwan Shamsudin, _eauthor. |
|
| 245 | 1 | 0 |
_aCO2 absorption performance of PVDF/alumina hollow fiber membrane for membrane contactor application / _cMuhammad Syazwan Shamsudin |
| 264 | 1 |
_aKuantan, Pahang : _bUMP, _c2017 |
|
| 264 | 4 | _c© 2017 | |
| 300 |
_axv, 47 pages : _billustrations (some color) ; _c30 cm. + _e1 CD-ROM |
||
| 336 |
_atext _2rdacontent |
||
| 336 |
_atext _2rdacontent |
||
| 337 |
_aunmediated _2rdamedia |
||
| 337 |
_acomputer _2rdamedia |
||
| 338 |
_avolume _2rdacarrier |
||
| 338 |
_acomputer disc _2rdacarrier |
||
| 347 |
_atext file _bPDF _2rda |
||
| 500 | _aFaculty of Chemical & Natural Resources Engineering | ||
| 502 | _aProject Paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2017 | ||
| 504 | _aIncludes bibliographical references | ||
| 520 | 3 | _aIn this study, fabrication of composite polyvinylidene fluoride (PVDF) hollow fiber membrane for carbon dioxide (CO2) absorption was successfully prepared via incorporating alumina clay as additive into polymer dope solution. 18 wt.% of PVDF hollow fiber membrane and 82wt. % of NMP was fabricated with various compositions of alumina clay (1 wt. %, 3 wt. % and 5 wt. %) via wet spinning process. The prepared membrane was characterized via contact angle and CO2 absorption performance was conducted at various monoethanolamine (MEA) concentrations and liquid flow rates. The hollow fiber membrane sample with 5% of alumina content (S4) showed the highest value around 92.4° when characterized via contact angle. The high value of the contact angle showed that the membrane has a high hydrophobicity which capable of reducing membrane wetting. The CO2 absorption at various flowrates and concentrations of MEA exhibited increasing trend of CO2 absorption flux upon addition of alumina clay concentration. The highest value of CO2 absorption flux recorded was 4.368 × 10−2 mol/m²s for the sample of PVDF/alumina with 5wt. % of alumina at 200 mL/min and 2M of MEA. | |
| 610 | 2 | 0 |
_aFaculty of Chemical & Natural Resources Engineering _xDissertations |
| 650 | 0 |
_aUniversities and Colleges _xDissertations |
|
| 650 | 0 | _aTheses | |
| 999 |
_aVIRTUA40 _c7413 _d7419 |
||
| 999 | _aVTLSSORT0080*0200*0400*0900*1000*2450*2640*2641*3000*3360*3361*3370*3371*3380*3381*3470*5000*5020*5040*5200*6100*6500*6501*9992 | ||