000 03107ntm a2200349 i 4500
001 vtls000103616
003 KUKTEM
005 20251117113404.0
008 180524s2018 my a f a m 000 0 eng d
020 _aTHE0000671(Local)
039 9 _a201905161631
_bnazirah
_y201805241516
_zfateeha
040 _aUMP
_beng
_cUMP
_erda
090 _aFKASA .S25 2018 r Bc.
100 1 _aSaleh Al Waeel, Osamah Najib,
_eauthor.
245 1 0 _aEffects of shear reinforcement on modolus of rupture in concrete beam /
_cOsamah Najib Saleh Al Waeel
264 1 _aKuantan, Pahang :
_bUMP,
_c2018
300 _axv, 42 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD ROM
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelor Degree in Civil Engineering) -- Universiti Malaysia Pahang – 2018
504 _aIncludes bibliographical references
520 3 _aThe flexural strength is one of the mechanical properties of concrete. The flexural strength of concrete is needed to determine the maximum deflection and also maximum loads that concrete can maintain at certain times. Shear reinforcements, which are nor-mally provided as vertical stirrups, are placed at varying intervals depending upon the shear conditions acting on a beam. The flexural failure in reinforced concrete beams does not happen suddenly but instead it shows some warning of distress that will occur in the near future. Contradictory to this, the shear failure is sudden, catastrophic and devastat-ing. To avoid any such sudden shear failure, shear reinforcements are provided. Also, the shear reinforcement has a control over the shear strength of the beam. The shear stirrups and are used to increase the shear strength of concrete beams, to avoid the shear failure and to cause a flexural failure. The main aim of this research is to study the effects of shear reinforcement on flexural strength in concrete beam. The concrete mixture used in the present study consists of cement, course aggregates, fine aggregates and water. Two types of tests i.e. compressive and flexural were carried out. The samples for compressive strength included cubes with size of 150 mm x 150 mm x 150 mm, while the size of the beams used for flexural strength tests were 150 mm width x 150mm depth x 750mm length. The results show there is no difference in flexural capacity between 3 shear links and 4 shear links, but when add 5 shear links we notice slight increase in the flexural capacity, it is concluded that the addition of links as shear reinforcement slightly effect the flexural capacity.
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and colleges
_xDisertations
650 0 _aTheses
999 _aVIRTUA40
_c7818
_d7824
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2640*3000*3360*3370*3371*3380*3381*3470*5000*5020*5040*5200*6100*6500*6501*9992