000 03173ntm a2200361 i 4500
001 vtls000105632
003 KUKTEM
005 20251117113409.0
008 190422t20182018my a f am 000 0 eng d
020 _aTHE0000610(Local)
039 9 _a201905161033
_bnazirah
_y201904220936
_znazri
040 _aUMP
_beng
_cUMP
_erda
090 _aFKASA .N673 2018 r Bc.
100 0 _aNorarina Noran,
_eauthor.
245 1 0 _aBehaviour of reinforced concrete beam with circular opening using different fraction volume of hybrid fibre /
_cNorarina Noran
264 1 _aKuantan, Pahang :
_bUMP,
_c2018
264 4 _c© 2018
300 _axii, 54 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD-ROM
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2018
504 _aIncludes bibliographical references
520 3 _aReinforced concrete beams with opening commonly used to facilitate essential services such as water supply pipes, drainage pipes, air conditioning electricity, telephone lines and computer network lines. The experimental work presented in this research is aimed to investigate experimentally the behaviour of beams with circular opening at the end of span. The research also conducted to study the potential of hybrid fibre in strengthening reinforced concrete beam using different fraction volume. The combination of steel fibre and kenaf fibre were used in this study. The study was carried out by casting beam with the addition of 0% hybrid fibre, 1% hybrid fibre and 2% hybrid fibre on the mixture of reinforced concrete beam. 18 cubes of all sides equal to 150 mm and 4 beams of dimensional 400x250x1200 mm were casted. All cubes specimens was tested until failure in compression machine. The beams were casted for 28 days and undergo flexural test. All the samples were tested and results were analysed using Microsoft Excel and presented with the aid of tables and graph. The study shows that, the reinforced concrete beam with the addition of hybrid fibre can sustain more than 200kN of load. However, the addition of hybrid fibre in concrete mix showed insignificant effect in compressive strength. Reinforced concrete beam with hybrid fibre show better performance as there is no excessive cracking until the structure had failed. Mode of failure of the beam changed from brittle to a more ductile manner as the amount of steel fibres was increased in the concrete mix. In term of ductility, the ductility is enhanced as 1% hybrid fibre was added but there is a limit exist which additional fibres lead to less ductile.
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and colleges
_xDisertations
650 0 _aTheses
999 _aVIRTUA40
_c7966
_d7972
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2640*2641*3000*3360*3370*3371*3380*3381*3470*5000*5020*5040*5200*6100*6500*6501*9992