000 02848ntm a2200385 i 4500
999 _c90860
_d90866
003 MY-KuUP
005 20251125105402.0
006 t||||fr|||| 000 0
007 ta
008 191014t20192019my a|||fram|| 000 0 eng d
020 _aTHE0008119(Local)
_qhardback
040 _aUMP
_beng
_cUMP
_erda
090 _aFKASA .A46 2019 r Bc.
100 1 _aAlmekhlafi, Mohammed Ahmed,
_eauthor.
245 1 4 _aThe effect of palm oil clinker powder & cockle shell powder as cement replacement to concrete mechanical properties /
_cMohammed Ahmed Almekhlafi
246 3 _aThe effect of palm oil clinker powder and cockle shell powder as cement replacement to concrete mechanical properties
264 1 _aKuantan, Pahang :
_bUMP,
_c2019
264 4 _c© 2019
300 _axi, 45 pages :
_bIllustrations ;
_c30 cm. +
_e1 CD-ROM
336 _atext
_2rdacontent
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019
504 _aIncludes bibliographical references
520 3 _aConcrete materials have been of a significant concern through the past years and there has been a huge research on finding alternatives to the traditional materials. Among the most common materials to be substituted are palm oil clinker waste on form of powder due to a presence of silica (pozzolanic material) which helps uphold the strength of concrete and is available in Malaysia also cockle shell powder which consists of calcium carbonate in the form of aragonite and calcite. The objective of this research is to examine the concrete compressive strength and flexural using cockleshell and palm oil clinker as cement replacement with different proportion. For this research, there are six different percentages of palm oil clinker and cockleshell replacement in concrete mixture. For compressive strength test and flexural test, the concrete is tested on 7, and 28 days. The concrete mixture was designed according to ASTM C 109/C 109M standard with water cement ratio of 0.485. For compressive strength test, 36 cubes size 50mm x 50mm x 50mm were tested on 7, and 28 days each. Moreover, for flexural test, 36 concrete beam size 160mm x 40mm x 40mm were tested on 7 and 28 days for each test. This study found that the compressive and flexural strength were decrease by increasing palm oil clinker powder and cockle shell powder percentage as cement replacement.
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
942 _2lcc
_cPSM