000 03487ntm a2200373 i 4500
999 _c90861
_d90867
003 MY-KuUP
005 20251125105403.0
006 t||||fr|||| 000 0
007 ta
008 191014t20192019my a|||fram|| 000 0 eng d
020 _aTHE0008120(Local)
_qhardback
040 _aUMP
_beng
_cUMP
_erda
090 _aFKASA .A49 2019 r Bc.
100 1 _aAlzubeer, Mohammed Ahmed Mohammed,
_eauthor.
245 1 0 _aBiomethanation of sewage wastewater using ultrasonic memberane anaerobic system (UMAS) /
_cMohammed Ahmed Mohammed Alzubeer
264 1 _aKuantan, Pahang :
_bUMP,
_c2019
264 4 _c© 2019
300 _ax, 41 pages :
_bIllustrations ;
_c30 cm. +
_e1 CD-ROM
336 _atext
_2rdacontent
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019
504 _aIncludes bibliographical references
520 3 _aSewage wastewater is hard wastewater that contains a high amount of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solids (TSS) and volatile suspended solids (VSS). These vital parameters should be treated first before it is discharged into any waterways. There are many treatment methods implied until this decade with the traditional approach. Pond system is the most implied method due to its low cost. The sewage wastewater was treating to produce methane gas by using membrane anaerobic digestion method. But there will be membrane fouling problem caused by high amounts of total solids carried by the wastewater. Therefore the operating cost of the treatment plant it will be very high. Thus, Ultrasonic Membrane Anaerobic System (UMAS) is used as an alternative method to overcome this problem. The sewage wastewater was collected from Kuantan Water Indah and acclimatizing for 5 days before running the reactor, The row wastewater parameter was recorded, COD was 164.67 mg/L, and BOD was 17.4 mg/L, and TSS was 31 mg/L, and VSS was 6mg/L, the pH, pressure and temperature was kept being constant during the experiment within the values of 6.5 to 7.5, 2 to 3 bar and 35 to 46 ºC respectively. The performance of Ultrasonic Membrane Anaerobic System UMAS is evaluated on the ability of (UMAS) to treat these parameters. The UMAS must be operated daily for 5 hours operation per day. The experiment is done when the UMAS is achieving a steady state. The steady state is achieved on day 5. The performance of UMAS showed high COD removal efficiency with 97.4%. and BOD removal efficiency with 92%, TSS removal efficiency 97% and VSS removal efficiency 99% and the methane gas composition obtained was about 79%. Based on the result obtained after ten days of the experiment shows that UMAS can treat strength and low wastewater, with no membrane fouling problem and produce methane gas from sewage wastewater. Moreover, further works are required to provide more in-depth understanding of the mechanisms involved to facilitate the development of an optimum system applicable to the field of the wastewater treatment plant.
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
942 _2lcc
_cPSM