000 02898ntm a2200361 i 4500
999 _c90881
_d90887
003 MY-KuUP
005 20251125105404.0
006 t||||fr|||| 000 0
007 ta
008 191015t20192019my a|||fram|| 000 0 eng d
020 _aTHE0008301(Local)
_qhardback
040 _aUMP
_beng
_cUMP
_erda
090 _aFKASA .A2385 2019 r Bc.
100 1 _aMohammed Badraddin, Abdulmalek Khled,
_eauthor.
245 1 0 _aHydrochemical assessment of ground water quality at Kampong Jaya Gading /
_cAbdulmalek Khled Mohammed Badraddin
264 1 _aKuantan, Pahang :
_bUMP,
_c2019
264 4 _c© 2019
300 _aviii, 45 pages :
_billustrations ;
_c30 cm. +
_e1 CD-ROM
336 _atext
_2rdacontent
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019
504 _aIncludes bibliographical references
520 3 _aIn Malaysia, groundwater is one of the sources of clean water, other than fresh river water and rain. Thus, this research had been done to determine the groundwater quality and also the effective type of well that can contribute to the good quality of groundwater. The parameters were considered such as PH, Electrical Conductivity, Turbidity, TDS, TSS, COD, BOD, manganese, iron, copper, zinc, lead, nitrate, total coliform and E.coli in this study. The water samples were collected from three different wells. The results were compared to the National Drinking Water Quality Standard (NDWQS) to know the class of the groundwater for each well. The result showed that the groundwater had been contaminated by the chromium with concentration of 1.59 mg/L which found in all wells. This result considered as relatively not in very high concentration even the concentration of element is higher than the standard stated by National Drinking Water Quality Standard (NDWOS). Meanwhile. for biological analysis result showed that total coliform and E.coli have highest contamination which was found in open wells with total coliform concentration 28 MPN/100 mL in opened well and 14 MPN/100 mL in closed well .E.coli concentration is 8.6 MPN/100 mL and 0MPN/100 mL in closed wells . As the conclusion, the groundwater quality was harmless from heavy metal concentration but highly contaminated with total coliform and E. coli. Quality of groundwater is equally important to its quantity owing to the suitability of water for various purposes.
610 2 0 _2Faculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and colleges
_xDisertations
650 0 _aTheses
942 _2lcc
_cPSM