245 1 0 _aEffect of perforations on cold-formed steel built-up i-section /
_cWan Mohamad Izzuan Wan Kamaludin
264 1 _aKuantan, Pahang :
_bUMP,
_c2018
264 4 _a© 2018
300 _axi, 53 pages :
_bIllustrations (some color) ;
_c30 cm. +
_e1 CD-ROM
336 _2rdacontent
_atext
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
337 _2rdamedia
_acomputer
338 _2rdacarrier
_avolume
338 _2rdacarrier
_acomputer disc
347 _2rda
_atext file
_bPDF
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang – 2018
504 _aIncludes bibliographical references
520 3 _aCold-formed steel comes with various type of section based on their function and purpose in construction work. There are three main types of sections which are single open section, open built-up section and closed built-up section. This research will be concentrating on open built-up section or I-section. Structural members of cold-formed steel usually come with the presence of perforations. Perforations are a hole or opening that are made on the cold-formed steel to ease construction work. It usually provided with different shapes and size based on its function such as to accommodate electrical, plumbing and air conditioner or heating services. However, the presence of perforations may cause a reduction in strength of individual component elements and the overall strength of the member depending on the position, size and orientation of the opening. This research will focus on the effect of position and shape of the perforations on the structural strength of the axially loaded cold-formed steel column. An experimental investigation of cold-formed steel subjected to compression loading to study the effect of perforations on the load capacity of column members of built-up I-section is held. A total of 6 samples that have different position of perforations were tested in this experiment. Each member has nominal thickness of 1.2 mm, column length of 600 mm and was compressed between a simply supported ends at both end. The result of this experiment shows that the ultimate load of each sample varies greatly on the perforation position. The result is presented in three sections which are load vs vertical displacement, load vs horizontal displacement and buckling behavior.