000 03169nam a22003617a 4500
999 _c91087
_d91093
003 MY-KuUP
005 20251125105421.0
007 ta
008 191107t20182018my a|||| |||| 00| 0 eng d
020 _aTHE0008270(Local)
040 _aUMP
_beng
_cUMP
_erda
090 _aFKASA .A756 2018 r Bc.
100 0 _aArina Fatin Hasan,
_eauthor.
245 1 0 _aEffect of earthing material water content on the resistivity and corrosion behaviour of earthing electrode /
_cArina Fatin Hasan
264 1 _aKuantan, Pahang :
_bUMP,
_c2018
264 4 _a© 2018
300 _axii, 40 pages :
_bIllustrations (some color) ;
_c30 cm. +
_e1 CD-ROM
336 _2rdacontent
_atext
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
337 _2rdamedia
_acomputer
338 _2rdacarrier
_avolume
338 _2rdacarrier
_acomputer disc
347 _2rda
_atext file
_bPDF
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang – 2018
504 _aIncludes bibliographical references
520 3 _aElectrical earthing systems main purposes is to disperse flow of charge to mother earth within the shortest time possible at the event of lightning or fault. Low frequency of earthing resistance of an electrical earthing systems determine its efficiency. Thus, there have been enormous amount of studies conducted on various material in order to find the best performing materials for an earthing systems. This study aims to determine the effect of varying water content on the electrical resistivity of earthing materials, determining the effect of suction on the corrosion behavior of copper and aluminium electrodes buried under earthing materials as well as identifying the type of corrosion induced microbes in earthing materials that is responsible for the corrosion of the earthing electrode. Two sample were used in this study namely Andrassy bentonite and Marconite. The sample electrical properties were studied by Wenner-four point test. The sample soil-water characteristic curve (SWCC) was established by Vapour Equilibrium Technique (VET). The sample biological characteristics was determined by means of spread plate method. The study outcome indicates that Andrassy Bentonite electrical resistivity is highly affected by water presence while Marconite electrical resistivity does not affected by the water presence. Aluminium and copper electrode corrosion behaviour is not affected solely by the water content of the earthing material, instead it is governs by a few other factors such as surrounding environment, sulphur content, pH, the presence of microorganisms and etc. One species of bacteria (i.e. Micrococcus luteus) and four species of fungus (i.e. Paecilomyces lilacinus, Trichoderma atroviride, Fusarium proliferatum, and Rhodotorula mucilaginosa) are the corrosion induced microbes that is responsible for corrosion of earthing electrode, identified in this study.