000 02957ntm a2200373 i 4500
999 _c92622
_d92628
003 MY-KuUP
005 20251125105556.0
006 t||||fr|||| 000 0
007 ta
008 200715t20192019my a|||fram|| 000 0 eng d
020 _aTHE0008753(Local)
_qhardback
040 _aUMP
_beng
_cUMP
_erda
090 _aFKASA .F66 2019 r Bc.
100 1 _aFoo, Voon Hong,
_eauthor.
245 1 0 _aNitrogen removal efficiency in slaughterhouse wastewater by using upflow microaerobic sludge reactor /
_cFoo Voon Hong
264 1 _aKuantan, Pahang :
_bUMP,
_c2019
264 4 _c© 2019
300 _axii, 56 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD-ROM
336 _atext
_2rdacontent
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019
504 _aIncludes bibliographical references
520 3 _aRapid growth of the livestock industry has led to the increase number of slaughterhouses in Malaysia. The wastewater generated from slaughterhouse will contained a large amount of organic and inorganic pollutants which are harmful to the environment. Previous studies had been proved that upflow microaerobic sludge reactor (UMSR) had excellent results in treating piggery water with high ammonium (NH4+-N) and low chemical oxygen demand (COD) to total nitrogen (TN) ratio. In this study, a prototype of UMSR was constructed to treat the slaughterhouse wastewater with high NH4+-N concentration and high COD/TN ratio and to compare its nitrogen removal efficiency with the existing slaughterhouse’s wastewater treatment plant. The acclimation stage of the prototype was 60 days. The reactor was controlled in the microaerobic condition which the dissolved oxygen (DO) was maintained within the range of 0.3 mg/L to 1.0 mg/L and pH value within the range of 7.0-8.0. Influent samples and effluent samples on Day 61, Day 65 and Day 70 were taken from the prototype for analysis. Influent sample and effluent sample were taken from the wastewater treatment plant of Slaughterhouse Kuantan for the comparison. The average percentage removal rate of TN, NH4+-N, COD and biochemical oxygen demand (BOD) of the prototype were 78.28%, 83.57% ,80.59% and 25.30%, respectively. The removal rate of TN, NH4+-N, COD and BOD for existing treatment plant were 19.05% ,18.96%, 82.55% and 9.08%, respectively. In conclusion, the UMSR can perform well in treating high COD/TN ratio wastewater and even had better performance than existing treatment plant.
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDisertations
650 0 _aUniversities and colleges
_xDisertations
650 0 _aTheses
942 _2lcc
_cPSM