100 1 _aWan Nur Huda Aqilah Alias
_eauthor.
245 1 0 _aPerformance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control /
_cWan Nur Huda Aqilah Alias
264 1 _aKuantan, Pahang :
_bUMP,
_c2021
264 4 _c© 2021
300 _axv, 91 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD ROM
336 _atext
_2rdacontent
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _ardamedia
_2computer
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Electrical & Electronics Engineering
502 _aThesis (Master of Science) -- Universiti Malaysia Pahang – 2021
504 _aIncludes bibliographical references
520 3 _aThe advancement of technology and the increase in population have increased the demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean and sustained power in vast quantities from sustainable energy. Recently, PV systems are frequently used owing to its light and easy-to-install characteristics. Although it was proven auspicious, faults can happen on the grid side of a grid-connected PV system, causing overshoot DC voltage and overcurrent. Thus, stressing the electrical component, lessening the system’s power quality and inverter’s trip. Therefore, many FRT strategies have been introduced to overcome these issues. This thesis proposed a new approach to alleviate this matter by controlling zero switching state of NPC inverter while injecting reactive current to the grid. First, the development of a two-stage grid-connected PV system was stated and the effects of grid faults were deliberated. Some conventional FRT strategies employed in the grid-connected PV system were studied. Furthermore, the efficiency of the scheme was verified by comparing it with a conventional method using DC chopper. The results showed the proposed method could lessen the overshoot DC voltage and injecting reactive current to the grid. Also, the results shown were similar to those of the conventional method.