000 04432ntm a2200349 i 4500
999 _c96732
_d96738
003 MY-KuUP
005 20251125110015.0
006 t||||fr|||| 000 0
008 220215t2020 my ad||fr|||| 000 0 eng d
020 _aTHE0009103(Local).
_qhardback
040 _aUMP
_beng
_cUMP
_erda
090 _aFTKA .R37 2020 r Thesis
100 1 0 _aRasheed Abed Hammood,
_eauthor.
245 1 0 _aEffect of fibers in reinforced concrete deep beams with web opening /
_cRasheed Abed Hammood
264 1 _aKuantan, Pahang :
_bUMP,
_c2020
264 4 _c© 2020
300 _axix, 169 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD ROM
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aFaculty of Civil Engineering Technology
502 _aThesis (Master of Science) -- Universiti Malaysia Pahang – 2020
504 _aIncludes bibliographical references
520 3 _aOpenings in reinforced concrete beams are often needed to provide passage for utility ducts that accommodate essential services such as power supply, water supply, airconditioning and sewerage. The openings have practical necessities but they have negative effects on structure behaviour. The present study aims to investigate the structural performance of fibres and analysis the effect of fibres contented in the reinforced concrete deep beam with web opening. Test variables were different web opening. The openings were one square with size150 mm x150 mm and one rectangular with size 300 mm x150 mm located at either the mid-span or the end span of the deep beam. Two types of fibres considered in this study included steel and hybrid (50% steel-50% kenaf) fibres. Forty-two simply supported deep beam with dimensions of 125 mm x 450 mm x 1200 mm were constructed and tested to failure under four-point loading. One of these deep beams was tested without any web opening and without any addition of fibres to serve as a reference to study the effect of the presence of openings on deep beams with web opening. The fibres were added at the volume fractions of 0%, 1% and 2%. The test results indicated that, the addition of single and hybrid fibres to reinforce concrete deep beams have a significant contribution to improve the structural performance of the fibre reinforced concrete deep beams. The use of fibres leads to much slower growth of the critical diagonal cracks and enhances the load-carrying capacity of the deep beam. In terms of provision of openings in web of reinforced concrete deep beams the results showed that the highest reduce in ultimate load among beams with openings was about 33% and 42% due to the square and rectangular openings at end span, respectively comparison of control deep beam without opening. In terms of single steel fibre the results showed that the significant enhancement of the structural performance of reinforced concrete deep beams with square and rectangular opening at mid and end span was about 111 %, 132%, 46% and 72%, respectively with Vf = 1% of steel fibre, meanwhile with Vf = 2% of steel fibre was showed about 105 %, 124%, 70% and 103%, respectively. In terms of hybrid fibre the results was a significant enhancement of the structural performance of fibre reinforced concrete deep beams with the square and rectangular opening at mid and end span was about 87 %, 61%, 63% and 58% respectively, with Vf = 1% of hybrid fibre. While with Vf = 2% of hybrid fibre the results showed the significant enhancement with the square and rectangular opening at mid and end span was about 38 %, 22%, 38% and 40%, respectively. This investigation demonstrated the ability of reinforced concrete deep beams with web opening using single and hybrid fibres to regain the deep beams capacity, using most economical resources (eco-friendly). Finally, the finding exhibited a significant enhancement of the structural capacity of reinforced concrete deep beams with web opening with Vf = 1% of hybrid fibre.
610 2 0 _aFaculty of Civil Engineering Technology
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
942 _2lcc
_cTHESIS