000 04297ntm a2200361 i 4500
999 _c97106
_d97112
003 MY-KuUP
005 20251125110041.0
006 t||||fr|||| 000 0
008 220428s2021 my a|||frm||| 000 0 eng d
020 _aTHE0009353(Local)
_qhardback
040 _aUMP
_beng
_cUMP
_erda
090 _aKK .M33 2021 r Thesis
100 1 _aNurmadiha Osman,
_eauthor.
245 1 0 _aEvaluation of arima and ann stream analytics for air quality monitoring system /
_cNurmadiha Osman
264 1 _aKuantan, Pahang :
_bUMP,
_c2021
264 4 _c© 2021
300 _axv, 186 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD ROM
336 _atext
_2rdacontent
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
337 _acomputer
_2rdamedia
338 _avolume
_2rdacarrier
338 _acomputer disc
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aCollege of Engineering
502 _aThesis (Master of Science) -- Universiti Malaysia Pahang – 2021
504 _aIncludes bibliographical references
520 3 _aThere are many environmental monitoring systems available in the market with Internetof-Things (IoT) enabled technology. However, the existing system is not equipped with online data analytics. Some of them provide analytics but are done in offline mode through third-party software or devices known as batch analytics. Pricewise, the existing monitoring system alone is expensive even though none of them are furnished with stream analytics. The thesis presents the design and development of an accurate air quality monitoring system equipped with streaming machine learning predictive analytics called Smart Environmental System (SES). The developed SES is divided into two sections End-Node Unit (ENU) and Gateway Unit (GWU). ENU consisted of calibrated sensors of NO2, CO, CO2, PM2.5, PM10, O3, temperature humidity integrated with Raspberry Pi Single-Board Computer (SBC) and Long-Range (LoRa) Transmitter (Tx) module. Meanwhile, GWU consisted of Raspberry Pi SBC, LoRa Receiver (Rx) and 4G module. The ENU transferred the data wirelessly to the GWU through LoRa communication, and GWU stored the data immediately in MySQL, which was installed in the Linux Apache MySQL PHP (LAMP) server. Investigation on evaluating senso rs’ accuracy is executed by comparing the collected data by SES vs data from the Department of Environment (DoE). The SES’s accuracy percentage error of CO, NO2, O3, PM10 are 5.1%, 7%, 6.1% and 6% correspondingly compared to DoE. Such accuracy of sensors is acceptable with an accuracy below 10%. Once accuracy has been validated, the data stored in MySQL database is successfully exported to the R query table in R-Server by using dbGetQuery() command, checked and aligned with the MySQL database. It is observed that the data in MySQL are successfully exported to the R query table based on the similar number of variables between those two tables. The data stored in the query table act as input to the analytics algorithm, which runs in R-server as well. In this thesis, two algorithms have been implemented and compared. Auto -Regressive Integrated Moving Average (ARIMA) and Artificial Neural Network (ANN). It is identified that ARIMA has better prediction accuracy (PA) percentage of 99.45%, 99.87%, 99.75%, 98.92% for CO, NO2, O3 and PM10 over ANN thus chosen as a predictive analytics algorithm for SES. Once embedded in SES, ARIMA performances are evaluated based on Mean Absolute Percentage Error (MAPE) and Prediction Accuracy (PA). It is observed that ARIMA MAPE is 1.64%,9.67%, 9.59%, 7.09%, for CO, NO2, O3 and PM10, respectively which led PA to achieve 96.78%, 90.33%, 90.41% and 92.91% correspondingly. The results proved that the proposed SES is able to precisely predict those gases for the next 24 hours above the 90% prediction accuracy. It can be concluded the proposed SES could be implemented as a future for the Air Pollutant Index (API) system.
610 2 0 _aCollege of Engineering
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
942 _2lcc
_cTHESIS