000 03703nam a2200349 i 4500
999 _c97114
_d97120
003 MY-KuUP
005 20251125110042.0
006 a||||fr|||| 001 0
007 ta
008 220428t20212021my a|||fram|| 001 0 eng d
020 _aTHE0009329(Local)
040 _aUMP
_beng
_cUMP
_erda
090 _aKK .A45 2021 r Thesis
100 1 _aAli Abdallah Ali Emhemed,
_eauthor.
245 1 0 _aOptimal distributed generation and load shedding scheme using artificial bee colony- hill climbing algorithm considering voltage stability and losses indices /
_cAli Abdallah Ali Emhemed
264 1 _aKuantan, Pahang :
_bUMP,
_c2021
264 4 _a© 2021
300 _axvi, 207 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD ROM
336 _atext
_2rdacontent
337 _aunmediated
_2rdamedia
338 _avolume
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aCollege of Engineering
502 _aThesis (Doctor of Philosophy) -- Universiti Malaysia Pahang – 2021
504 _aIncludes bibliographical references
520 3 _aAround the world, the demand is increasing due to industrial activity and advances in both developing and developed countries. This situation has pushed many power system operators to operate their system closer to the voltage stability limits. Increase in power consumption can cause serious problems in electric power systems, such as voltage instability, frequency instability, line overloading, and power system blackouts.Voltage stability index (VSI) is a tool for detecting voltage stability related problems. This work proposes an index of the line voltage stability limits based on Thevenin’s Theorem, which is referred to as the Maximum Line Stability Index (MLSI). The function of MLSI is to estimate the voltage stability condition and determine sensitive lines in power system. To increase voltage stability and improve other aspects of power quality, many power system operators are considering the idea of integrating distributed energy resources into the existing power system. Another part of this work focuses on enhancing the stability of the power system using distributed generator (DG). The proposed solution is based on the optimization method developed from a combination of the Artificial Bee Colony and Hill Climbing algorithms (ABC-HC) to give the optimal placement and sizing of DG units to be deployed in the system. Under severe contingency conditions, such as increase in demand and loss of transmission lines, frequently the problem cannot be solved by just using the DG, the possible solution is to consider load shedding as to reduce the congestion in order to maintain voltage stability in the system. To solve this problem, an optimal load shedding approach, integrated with optimal DG sizing is proposed using the ABC-HC algorithm. This technique can find the load location to be shed, as well as the size of DG. The performance and effectiveness of each proposed solution was tested on IEEE test systems. The simulation results showed that the MLSI index has strong sensitivity to detect the overloaded line in the system and as reliable as other voltage stability indices. Meanwhile, the proposed ABC-HC optimization technique shows its ability to identify the bus location and the optimal active energy injection from the DG with a substantial power loss reduction. Finally, under severe contingency condition, the optimization of DGs and load shedding shows the system able to maintain its voltage stability.