000 04001ntm a2200361 i 4500
999 _c99760
_d99766
003 MY-KuUP
005 20251125110753.0
006 t||||fr|||| 000 0
007 ta
008 230718t20232023my a|||fr|||| 000 0 eng d
020 _aTHE0009667 (Local)
_qHardback
040 _beng
_cUMP
_erda
090 _aFTKKP .N33 2023 r Thesis
100 1 _aWan Nadja Julika Binti Wan Hamizan,
_eauthor.
245 1 0 _aDevelopment of prototype sensor for sugar adulteration detection in malaysian stingless bee honey /
_cWan Nadja Julika Binti Wan Hamizan
260 1 _aPahang :
_bUMP,
_c2022
264 4 _c©2022
300 _axvi,156 pages :
_bIllustration ;
_c30 cm.+
_e1-CD ROM
336 _2rdacontent
_atext
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
337 _2rdamedia
_acomputer
338 _2rdacarrier
_avolume
338 _2rdacarrier
_acomputer disc
347 _2rda
_atext file
_bPDF
500 _aFaculty of Chemical and Process Engineering Technology
502 _aThesis (Doctor of Philosophy) -- Universiti Malaysia Pahang – 2023
520 3 _aThe growing demand for honey in the market has resulted in tampering honey with foreign substances and increased production of artificial honey. There are lots of laboratory tests for honey adulteration. However, most of the tests are tedious, costly, and complicated. As a result, alternative approaches for faster and simpler detection of honey adulteration should be developed and conducted regularly. Herein, this research attempts to develop paper-based analytical devices (PADs) as a simple, rapid, and inexpensive method for simultaneously detecting glucose and sucrose adulteration in stingless bee honey. Prior to developing the PADs, eight stingless bee honey samples were characterized, including the physicochemical, enzymatic, and microbiological analyses. Based on the results, the properties of the honey samples are pH (pH 2.52–4.03), free acidity (61.1–257.8 meq/kg), moisture content (19.4–31.4%), electrical conductivity (0.03–1.08 mS/cm), ash content (0.34–0.83 g/100 g), hydroxymethylfurfural (35.4–456.6 mg/kg), diastase activity (2.78–6.25 DN), invertase activity (0.16–3.68 IN), fructose (2.21–54.6 g/100 g), glucose (2.66–14.1 g/100 g), and sucrose (0.39–22.9 g/100 g). For microbiological analyses, several honey samples were positive with several microbes, but the results still comply with the Malaysian Kelulut Standard. In order to develop the PADs, two approaches were used: paper-based electrochemical devices (PEDs) and colorimetric paper-based analytical devices (C-PADs). Both PADs only used a small amount of sample solution (1 and 8 μL) for both glucose-sucrose analyses. Furthermore, no interfering compound was obtained for both PEDs and C-PADs. The storage stability was further investigated, and after 30 days, the stability of glucose and sucrose PEDs decreased to 57.2% and 85.2% from their initial response, respectively. The C-PADs are more stable than the PEDs as the performance of glucose and sucrose for C-PADs only decreased by 60% and 40% from their initial values, respectively. Finally, the glucose and sucrose content of eight stingless bee honey samples was measured using the PEDs and C-PADs and compared with high-performance liquid chromatography (HPLC). The results for both PADs corroborated well with HPLC as most of the results are not significantly different at the 95% confidence level. For glucose PADs, the highest glucose levels were observed in H5, H6, and H7. Meanwhile, for sucrose PADs, the commercial samples H4, H5, and H8 were positive for honey adulteration. From this research, it can be concluded that the prototype PADs have been successfully developed to determine sugar adulteration in stingless bee honey.
610 2 0 _aFaculty of Chemical and Process Engineering Technology
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aThesis
_xDissertations
942 _2lcc
_cTHESIS