MARC details
| 000 -LEADER |
| fixed length control field |
02413nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000045879 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204429.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
100521t2009 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005675(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905211109 |
| Level of effort used to assign nonsubject heading access points |
hanafiah |
| Level of effort used to assign subject headings |
201107132321 |
| Level of effort used to assign classification |
VLOAD |
| -- |
201005211642 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA357 .Z36 2009 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Mohd Zamri Deraman |
| 245 10 - TITLE STATEMENT |
| Title |
Analysis of steady flow for various cerebral aneurysm size / |
| Statement of responsibility, etc. |
Mohd Zamri Deraman |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
Analysis of steady flow for various cerebral aneurysm size |
| Medium |
[electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2009 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiii, 88 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 computer disc |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 74-77 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Investigation on the changes of flow patterns in a blood vessel with a fixed fusiform aneurysm resulting from placement of a different size of aneurysm. The velocity profile and pressure distribution had been analysis from different size of aneurysm. Three different modeling of aneurysm had been analysis which is small, large, and giant. The diameter of small aneurysm is less 12mm. For the large aneurysm is between 12mm to 25mm of diameter. The giant sizes are about more 25mm in diametr. To identify the changes in local hemodynamics due to stent implantation, a stented and non stented aneurysm model was taken into considerations. The simulation of the model was studied under incompressible, Non-Newtonian, viscous, non pulsatile condition in which we investigated computationally in a three-dimensional configuration using a fluid dynamics program. Hence, the different size of aneurysm produces the different results of flow field in aneurysm. The velocity gets with different analysis from different size of diameter aneurysm. Different pressure distribution is feature from aneurysm that have different diameter. Aneurism that have big diameter will show changes in the pressure distribution graph. However, aneurysm that have small diameter can be detected using special device. Research and analysis parameter or other factor that influence flow in the aneurysm must be consider in future research. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Fluid dynamics |