Analysis of steady flow for various cerebral aneurysm size / Mohd Zamri Deraman

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2009Description: xiii, 88 p. : ill. (some col.) ; 30 cm. + 1 computer discISBN:
  • THE0005675(Local)
Other title:
  • Analysis of steady flow for various cerebral aneurysm size [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009 Abstract: Investigation on the changes of flow patterns in a blood vessel with a fixed fusiform aneurysm resulting from placement of a different size of aneurysm. The velocity profile and pressure distribution had been analysis from different size of aneurysm. Three different modeling of aneurysm had been analysis which is small, large, and giant. The diameter of small aneurysm is less 12mm. For the large aneurysm is between 12mm to 25mm of diameter. The giant sizes are about more 25mm in diametr. To identify the changes in local hemodynamics due to stent implantation, a stented and non stented aneurysm model was taken into considerations. The simulation of the model was studied under incompressible, Non-Newtonian, viscous, non pulsatile condition in which we investigated computationally in a three-dimensional configuration using a fluid dynamics program. Hence, the different size of aneurysm produces the different results of flow field in aneurysm. The velocity gets with different analysis from different size of diameter aneurysm. Different pressure distribution is feature from aneurysm that have different diameter. Aneurism that have big diameter will show changes in the pressure distribution graph. However, aneurysm that have small diameter can be detected using special device. Research and analysis parameter or other factor that influence flow in the aneurysm must be consider in future research.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB PEKAN TA357 .Z36 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000044351
Final Year Report Final Year Report UMPLIB PEKAN CD 4199 | TA357 .Z36 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000044352

Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009

Bibliography : p. 74-77

Investigation on the changes of flow patterns in a blood vessel with a fixed fusiform aneurysm resulting from placement of a different size of aneurysm. The velocity profile and pressure distribution had been analysis from different size of aneurysm. Three different modeling of aneurysm had been analysis which is small, large, and giant. The diameter of small aneurysm is less 12mm. For the large aneurysm is between 12mm to 25mm of diameter. The giant sizes are about more 25mm in diametr. To identify the changes in local hemodynamics due to stent implantation, a stented and non stented aneurysm model was taken into considerations. The simulation of the model was studied under incompressible, Non-Newtonian, viscous, non pulsatile condition in which we investigated computationally in a three-dimensional configuration using a fluid dynamics program. Hence, the different size of aneurysm produces the different results of flow field in aneurysm. The velocity gets with different analysis from different size of diameter aneurysm. Different pressure distribution is feature from aneurysm that have different diameter. Aneurism that have big diameter will show changes in the pressure distribution graph. However, aneurysm that have small diameter can be detected using special device. Research and analysis parameter or other factor that influence flow in the aneurysm must be consider in future research.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my