MARC details
| 000 -LEADER |
| fixed length control field |
01972nam a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000051735 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204441.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
110308t2010 my da f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0005820(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905131525 |
| Level of effort used to assign nonsubject heading access points |
aida |
| Level of effort used to assign subject headings |
201203211541 |
| Level of effort used to assign classification |
Fida |
| Level of effort used to assign subject headings |
201107140036 |
| Level of effort used to assign classification |
VLOAD |
| -- |
201103081212 |
| -- |
ida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TA418.84 .F55 2010 rs Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Muhamad Fikri Aziz Mat Lah |
| 245 10 - TITLE STATEMENT |
| Title |
Study of pipe connector effect in piping system / |
| Statement of responsibility, etc. |
Muhamad Fikri Aziz Mat Lah |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2010 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xv, 57 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 53 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
This thesis was carried out to investigate the effect of connecting pipes in a piping system using acoustic emission techniques. A plumbing system that is equipped with a number of connecting pipes was tested with acoustic emission sensors on the different fluid pressure. The sources of the acoustic emission signals (AE) is the activity prior to and after the fluid through connecting pipes and it is observed using acoustic sensors with a view of software USB E3.34.For study effects of pipe connections, all time domain parameters (maximum amplitude, power, RMS amplitude) of signals were observed and processed with the aid of Matlab software. All parameters were compared with the pressure of the fluid flow at eleven different points. The results showed that the difference between the AE parameters of high-flow pressure and low flow pressure is not much different. From this relationship, it may not conclude that the pipe connecting is the main factor to the difference in acoustic emission technique effects. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Accoustic emission testing |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Pipelines |