Study of pipe connector effect in piping system / Muhamad Fikri Aziz Mat Lah

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2010Description: xv, 57 p. : ill. (some col.) ; 30 cm. + 1 CD-ROMISBN:
  • THE0005820(Local)
Subject(s): Dissertation note: Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010 Abstract: This thesis was carried out to investigate the effect of connecting pipes in a piping system using acoustic emission techniques. A plumbing system that is equipped with a number of connecting pipes was tested with acoustic emission sensors on the different fluid pressure. The sources of the acoustic emission signals (AE) is the activity prior to and after the fluid through connecting pipes and it is observed using acoustic sensors with a view of software USB E3.34.For study effects of pipe connections, all time domain parameters (maximum amplitude, power, RMS amplitude) of signals were observed and processed with the aid of Matlab software. All parameters were compared with the pressure of the fluid flow at eleven different points. The results showed that the difference between the AE parameters of high-flow pressure and low flow pressure is not much different. From this relationship, it may not conclude that the pipe connecting is the main factor to the difference in acoustic emission technique effects.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB PEKAN CD 4966 | TA418.84 .F55 2010 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000053902
Final Year Report Final Year Report UMPLIB PEKAN TA418.84 .F55 2010 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000053901

Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010

Bibliography : p. 53

This thesis was carried out to investigate the effect of connecting pipes in a piping system using acoustic emission techniques. A plumbing system that is equipped with a number of connecting pipes was tested with acoustic emission sensors on the different fluid pressure. The sources of the acoustic emission signals (AE) is the activity prior to and after the fluid through connecting pipes and it is observed using acoustic sensors with a view of software USB E3.34.For study effects of pipe connections, all time domain parameters (maximum amplitude, power, RMS amplitude) of signals were observed and processed with the aid of Matlab software. All parameters were compared with the pressure of the fluid flow at eleven different points. The results showed that the difference between the AE parameters of high-flow pressure and low flow pressure is not much different. From this relationship, it may not conclude that the pipe connecting is the main factor to the difference in acoustic emission technique effects.