THD and efficiency study for PV grid-connected / (Record no. 3819)

MARC details
000 -LEADER
fixed length control field 01877nam a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000071491
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204536.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 130612t2012 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006712(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905171531
Level of effort used to assign nonsubject heading access points amirul
-- 201306121059
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TK1087 .L34 2012 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Lafsah Mat Daud
245 10 - TITLE STATEMENT
Title THD and efficiency study for PV grid-connected /
Statement of responsibility, etc. Lafsah Mat Daud
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. Universiti Malaysia Pahang,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent xviii, 117 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Electrical Engineering (Power System)) -- Universiti Malaysia Pahang - 2012
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 100-103
520 3# - SUMMARY, ETC.
Summary, etc. Total harmonic distortion (THD) is a measurement of the harmonic distortion and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. In general, efficiency is a measurable concept, quantitatively determined by the ratio of output to input. The project is all about the experimental study on THD and efficiency for photovoltaic (PV) grid connected. A scale-down less than 1kW system will be developed and established for the study. The impact on THD and efficiency will be assessed to the real network environment by connected three phase motor to Variable Frequency Drives (VFD’s) as the load. The experimental will be done by using Power Quality Analyzer (PQA) software and the comparison between before and after connected PV will be conducted. The results of the THD and efficiency for PV grid connected system will be obtained and analyzed under influence of load conditions.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Photovoltaic power
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Photovoltaic cells
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TK1087 .L34 2012 rs Bc. 0000071334 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 6752 | TK1087 .L34 2012 rs Bc. 0000071335 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us