THD and efficiency study for PV grid-connected / Lafsah Mat Daud

By: Material type: TextTextPublication details: Kuantan, Pahang : Universiti Malaysia Pahang, 2012Description: xviii, 117 p. : ill. ; 30 cm. + 1 CD-ROMISBN:
  • THE0006712(Local)
Subject(s): Dissertation note: Project paper (Bachelor of Electrical Engineering (Power System)) -- Universiti Malaysia Pahang - 2012 Abstract: Total harmonic distortion (THD) is a measurement of the harmonic distortion and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. In general, efficiency is a measurable concept, quantitatively determined by the ratio of output to input. The project is all about the experimental study on THD and efficiency for photovoltaic (PV) grid connected. A scale-down less than 1kW system will be developed and established for the study. The impact on THD and efficiency will be assessed to the real network environment by connected three phase motor to Variable Frequency Drives (VFD’s) as the load. The experimental will be done by using Power Quality Analyzer (PQA) software and the comparison between before and after connected PV will be conducted. The results of the THD and efficiency for PV grid connected system will be obtained and analyzed under influence of load conditions.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB PEKAN TK1087 .L34 2012 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000071334
Final Year Report Final Year Report UMPLIB PEKAN CD 6752 | TK1087 .L34 2012 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000071335

Project paper (Bachelor of Electrical Engineering (Power System)) -- Universiti Malaysia Pahang - 2012

Bibliography : p. 100-103

Total harmonic distortion (THD) is a measurement of the harmonic distortion and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. In general, efficiency is a measurable concept, quantitatively determined by the ratio of output to input. The project is all about the experimental study on THD and efficiency for photovoltaic (PV) grid connected. A scale-down less than 1kW system will be developed and established for the study. The impact on THD and efficiency will be assessed to the real network environment by connected three phase motor to Variable Frequency Drives (VFD’s) as the load. The experimental will be done by using Power Quality Analyzer (PQA) software and the comparison between before and after connected PV will be conducted. The results of the THD and efficiency for PV grid connected system will be obtained and analyzed under influence of load conditions.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us