Pressure drop study on tubing for gas flow / (Record no. 3895)

MARC details
000 -LEADER
fixed length control field 01850nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000075763
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204538.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 131028t2013 my da f abm 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0003601(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905152039
Level of effort used to assign nonsubject heading access points zulaiha
-- 201310281646
-- nabilah
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ1025 .A36 2013 rs Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nur'Ain Hassan
245 10 - TITLE STATEMENT
Title Pressure drop study on tubing for gas flow /
Statement of responsibility, etc. Nur'Ain Hassan
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 79 p. :
Other physical details ill. ;
Dimensions 30 cm. +
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang – 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 73-75
520 3# - SUMMARY, ETC.
Summary, etc. Nowadays, tubing was majorly used for pipe replacement in gas industrial or commercial building. This study is to compute pressure drop of gas flow on tube with nitrogen; non-flammable gas, carbon dioxide and oxygen gas as medium. It was conducted on several tubes, 3/8 inch, 1/2 inch, 3/4 inch, 1 inch, and 1 1/2 inch outside diameter size respectively. The data was calculated based on pressure drop mathematical formula. The flow rate was manipulated in order to determine the pressure drop. The pressure was kept constant at 25 psig, 50 psig and 100 psig. A computer simulation also developed to effectively design of the process. The computer simulation was conducted to compute pressure drop at higher pressure, flow rate and size of tube. Data of pressure drop that obtained for each of type gas flow was increases as the flow rate increase and decrease as well as the diameter of tube increase. Results that were obtained can be used as reference and guidance for the designer of gas pipeline.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Gas flow
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TJ1025 .A36 2013 rs Bc. 0000076157 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   CD 7340 | TJ1025 .A36 2013 rs Bc. 0000076158 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us