Analysis on the performance of adsorption route in a tropical region / (Record no. 4944)

MARC details
000 -LEADER
fixed length control field 02881ntm a2200253 a 4500
001 - CONTROL NUMBER
control field vtls000081886
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204614.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 141009t2013 my a f m 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0006042(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905151229
Level of effort used to assign nonsubject heading access points aida
Level of effort used to assign subject headings 201411051134
Level of effort used to assign classification safura
-- 201410091001
-- Fida
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ163.5.B84 N87 2013 r Bc.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Wan Nurlisa Wan Ahmad
245 10 - TITLE STATEMENT
Title Analysis on the performance of adsorption route in a tropical region /
Statement of responsibility, etc. Wan Nurlisa Wan Ahmad
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent xiv, 59 p. :
Other physical details ill. (some col.) ;
Dimensions 30 cm.+
Accompanying material 1 CD-ROM
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Mechanical Engineering (Automotive) -- Universiti Malaysia Pahang - 2013
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography : p. 58-59
520 3# - SUMMARY, ETC.
Summary, etc. Nowadays, adsorption chiller attracts attention to be used in cooling system in tropical region due to their minimum heat required and environmental friendlycharacteristics. The objectives in these studies are to study about the stable solar drivencooling system by adsorption route in a tropical region and to study about theperformance of cooling system in the tropical region. The complete cooling system flowis starting from the solar intensity, then absorb by the solar plate collector, the energy isdirectly stored to the storage water tank to be used for the two beds of the adsorption chiller and lastly it will be supplied cooling energy to the residential building. Solar data and residential cooling load in the tropical region are obtained from the journal. In order to get the best performance of cooling system in term of cost and emission produce, there are 3 difference cases that used different component and energy source. By using the storage water tank as a main component to store the energy from the solar plate collector, two auxiliary components are also chosen when the volume of the storage water tank is reduced to 60% and 30% from the original volume, they are electric heater and natural gas boiler. It is another alternative to get higher heat energy in the water storage and they also act as a backup system for the solar plate collector. The best cooling system in term of cost and emission produce is the boiler with 30% reduction of original volume storage water tank which is RM 2355 for the installation and RM15.98 per month for energy cost. While, monthly cost for conventional air-conditioning is RM333.54 that used 55kW for the whole residential building. For the emission produce per month for this case are 33g for CO 2 , 1.97g for CO and 3.61g for NO , it is contrast with conventional air-conditioning which is 1446.56g for CO 13.63g for CO, and 9.34g for NO X.2, X
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Building
General subdivision Energy conservation
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Air conditioning
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   TJ163.5.B84 N87 2013 r Bc. 0000086541 04/09/2019 1 04/09/2019 Final Year Report
  Not lost   Not for loan UMPLIB PEKAN UMPLIB PEKAN 04/09/2019   CD 8210 | TJ163.5.B84 N87 2013 r Bc. 0000086542 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us