MARC details
| 000 -LEADER |
| fixed length control field |
02881ntm a2200253 a 4500 |
| 001 - CONTROL NUMBER |
| control field |
vtls000081886 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
KUKTEM |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251114204614.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
141009t2013 my a f m 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0006042(Local) |
| 039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE] |
| Level of rules in bibliographic description |
201905151229 |
| Level of effort used to assign nonsubject heading access points |
aida |
| Level of effort used to assign subject headings |
201411051134 |
| Level of effort used to assign classification |
safura |
| -- |
201410091001 |
| -- |
Fida |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
TJ163.5.B84 N87 2013 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Wan Nurlisa Wan Ahmad |
| 245 10 - TITLE STATEMENT |
| Title |
Analysis on the performance of adsorption route in a tropical region / |
| Statement of responsibility, etc. |
Wan Nurlisa Wan Ahmad |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Kuantan, Pahang : |
| Name of publisher, distributor, etc. |
UMP, |
| Date of publication, distribution, etc. |
2013 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiv, 59 p. : |
| Other physical details |
ill. (some col.) ; |
| Dimensions |
30 cm.+ |
| Accompanying material |
1 CD-ROM |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project paper (Bachelor of Mechanical Engineering (Automotive) -- Universiti Malaysia Pahang - 2013 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Bibliography : p. 58-59 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
Nowadays, adsorption chiller attracts attention to be used in cooling system in tropical region due to their minimum heat required and environmental friendlycharacteristics. The objectives in these studies are to study about the stable solar drivencooling system by adsorption route in a tropical region and to study about theperformance of cooling system in the tropical region. The complete cooling system flowis starting from the solar intensity, then absorb by the solar plate collector, the energy isdirectly stored to the storage water tank to be used for the two beds of the adsorption chiller and lastly it will be supplied cooling energy to the residential building. Solar data and residential cooling load in the tropical region are obtained from the journal. In order to get the best performance of cooling system in term of cost and emission produce, there are 3 difference cases that used different component and energy source. By using the storage water tank as a main component to store the energy from the solar plate collector, two auxiliary components are also chosen when the volume of the storage water tank is reduced to 60% and 30% from the original volume, they are electric heater and natural gas boiler. It is another alternative to get higher heat energy in the water storage and they also act as a backup system for the solar plate collector. The best cooling system in term of cost and emission produce is the boiler with 30% reduction of original volume storage water tank which is RM 2355 for the installation and RM15.98 per month for energy cost. While, monthly cost for conventional air-conditioning is RM333.54 that used 55kW for the whole residential building. For the emission produce per month for this case are 33g for CO 2 , 1.97g for CO and 3.61g for NO , it is contrast with conventional air-conditioning which is 1446.56g for CO 13.63g for CO, and 9.34g for NO X.2, X |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Building |
| General subdivision |
Energy conservation |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Air conditioning |