Analysis on the performance of adsorption route in a tropical region / Wan Nurlisa Wan Ahmad

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2013Description: xiv, 59 p. : ill. (some col.) ; 30 cm.+ 1 CD-ROMISBN:
  • THE0006042(Local)
Subject(s): Dissertation note: Project paper (Bachelor of Mechanical Engineering (Automotive) -- Universiti Malaysia Pahang - 2013 Abstract: Nowadays, adsorption chiller attracts attention to be used in cooling system in tropical region due to their minimum heat required and environmental friendlycharacteristics. The objectives in these studies are to study about the stable solar drivencooling system by adsorption route in a tropical region and to study about theperformance of cooling system in the tropical region. The complete cooling system flowis starting from the solar intensity, then absorb by the solar plate collector, the energy isdirectly stored to the storage water tank to be used for the two beds of the adsorption chiller and lastly it will be supplied cooling energy to the residential building. Solar data and residential cooling load in the tropical region are obtained from the journal. In order to get the best performance of cooling system in term of cost and emission produce, there are 3 difference cases that used different component and energy source. By using the storage water tank as a main component to store the energy from the solar plate collector, two auxiliary components are also chosen when the volume of the storage water tank is reduced to 60% and 30% from the original volume, they are electric heater and natural gas boiler. It is another alternative to get higher heat energy in the water storage and they also act as a backup system for the solar plate collector. The best cooling system in term of cost and emission produce is the boiler with 30% reduction of original volume storage water tank which is RM 2355 for the installation and RM15.98 per month for energy cost. While, monthly cost for conventional air-conditioning is RM333.54 that used 55kW for the whole residential building. For the emission produce per month for this case are 33g for CO 2 , 1.97g for CO and 3.61g for NO , it is contrast with conventional air-conditioning which is 1446.56g for CO 13.63g for CO, and 9.34g for NO X.2, X
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB PEKAN TJ163.5.B84 N87 2013 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000086541
Final Year Report Final Year Report UMPLIB PEKAN CD 8210 | TJ163.5.B84 N87 2013 r Bc. (Browse shelf(Opens below)) 1 Not for loan 0000086542

Project paper (Bachelor of Mechanical Engineering (Automotive) -- Universiti Malaysia Pahang - 2013

Bibliography : p. 58-59

Nowadays, adsorption chiller attracts attention to be used in cooling system in tropical region due to their minimum heat required and environmental friendlycharacteristics. The objectives in these studies are to study about the stable solar drivencooling system by adsorption route in a tropical region and to study about theperformance of cooling system in the tropical region. The complete cooling system flowis starting from the solar intensity, then absorb by the solar plate collector, the energy isdirectly stored to the storage water tank to be used for the two beds of the adsorption chiller and lastly it will be supplied cooling energy to the residential building. Solar data and residential cooling load in the tropical region are obtained from the journal. In order to get the best performance of cooling system in term of cost and emission produce, there are 3 difference cases that used different component and energy source. By using the storage water tank as a main component to store the energy from the solar plate collector, two auxiliary components are also chosen when the volume of the storage water tank is reduced to 60% and 30% from the original volume, they are electric heater and natural gas boiler. It is another alternative to get higher heat energy in the water storage and they also act as a backup system for the solar plate collector. The best cooling system in term of cost and emission produce is the boiler with 30% reduction of original volume storage water tank which is RM 2355 for the installation and RM15.98 per month for energy cost. While, monthly cost for conventional air-conditioning is RM333.54 that used 55kW for the whole residential building. For the emission produce per month for this case are 33g for CO 2 , 1.97g for CO and 3.61g for NO , it is contrast with conventional air-conditioning which is 1446.56g for CO 13.63g for CO, and 9.34g for NO X.2, X

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my