Comparison of wind load on building surface according to wind tunnel and MS1553:2002 (wind loading for building structure in Malaysia) / (Record no. 697)

MARC details
000 -LEADER
fixed length control field 01592nam a2200241 a 4500
001 - CONTROL NUMBER
control field vtls000029633
003 - CONTROL NUMBER IDENTIFIER
control field KUKTEM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251114204348.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 080623s2007 my f 001 0 eng|d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number THE0003592(Local)
039 #9 - LEVEL OF BIBLIOGRAPHIC CONTROL AND CODING DETAIL [OBSOLETE]
Level of rules in bibliographic description 201905152032
Level of effort used to assign nonsubject heading access points zulaiha
Level of effort used to assign subject headings 201107132034
Level of effort used to assign classification VLOAD
Level of effort used to assign subject headings 200908141504
Level of effort used to assign classification VLOAD
Level of effort used to assign subject headings 200908141434
Level of effort used to assign classification VLOAD
-- 200806231238
-- fara
040 ## - CATALOGING SOURCE
Original cataloging agency UMP
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) TJ820 .T46 2007 rs Thesis
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Teoh Wei Bing
245 10 - TITLE STATEMENT
Title Comparison of wind load on building surface according to wind tunnel and MS1553:2002 (wind loading for building structure in Malaysia) /
Statement of responsibility, etc. Teoh Wei Bing
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kuantan, Pahang :
Name of publisher, distributor, etc. UMP,
Date of publication, distribution, etc. 2007
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 47 p. :
Other physical details col. ill. ;
Dimensions 30 cm.
502 ## - DISSERTATION NOTE
Dissertation note Project paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang - 2007
520 3# - SUMMARY, ETC.
Summary, etc. One of the major consideration factors in designing the tall building is wind load. This study is conducted to determine the validation of wind tunnel testing. A square building is tested in wind tunnel to determine the force distribution pattern on the building surfaces. The experiment result is compared to the MS1553:2002 (Code of Practice on Wind Loading for Building Structure), for which real building had been tested. The experiment result shows similar pattern in the force distribution as derived from MS1553:2002. It shows that the wind tunnel can be used to design wind load acting on tall building. -Author
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Wind power
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Sustainable architecture
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Date acquired Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
  Not lost   Not for loan UMPLIB GAMBANG UMPLIB GAMBANG 04/09/2019   TJ820 .T46 2007 rs Thesis 0000030358 04/09/2019 1 04/09/2019 Final Year Report

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us