MARC details
| 000 -LEADER |
| fixed length control field |
02780nam a22003617a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251125105402.0 |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
| fixed length control field |
ta |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
191014t20182018my a|||| |||| 00| 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0008217(Local) |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FKASA .L93 2018 r Bc. |
| 100 0# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Nur Lyana Adibah Mushiwan, |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Potential study of Bera Lake water quality for alternative source of water supply / |
| Statement of responsibility, etc. |
Nur Lyana Adibah Mushiwan |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2018 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
© 2018 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xii, 56 pages : |
| Other physical details |
Illustrations (some color) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD-ROM |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
unmediated |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
computer |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
volume |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
computer disc |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| Source |
rda |
| File type |
text file |
| Encoding format |
PDF |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Civil Engineering and Earth Resources |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Project Paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang – 2018 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
This study concentrated on deciding potential of Bera Lake water quality for alternative source of water supply. Water quality is an important reference for describing the physical, chemical, and biological properties of water classification into each class. A study was conducted on physical, chemical, and biological parameter of Bera Lake on 2018 that contain water bodies at two stations with two sampling in two months of February and April 2018. Physical parameters were temperature and total suspended solids. Then, chemical parameters were pH value, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), ammonia nitrogen, phosphorus and selected heavy metals such as zinc, copper, cadmium and lead. For biological parameter were Total Coliform and E. Coli. The water was classified based on Water Quality Index (WQI) and National Water Quality for Malaysia (NWQS). Based on WQI standard, classifications of water quality were based on type of class. After accomplishment the laboratory test, two stations in Bera Lake can being determined classified into class 2. Station 1 with 79.33 is for class 2, if use for water supply need conventional treatment. Station 2 with 79.24 also in class 2. If want to being as water supply the conventional treatment were needed. Overall, identifying water quality is important for differentiate suitable purpose of water body. It is very important for conserving and preserve source of surface water for water supply purposes in a future. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Civil Engineering and Earth Resources |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Dissertations |
| General subdivision |
Universities and colleges |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Final Year Report |