Potential study of Bera Lake water quality for alternative source of water supply / Nur Lyana Adibah Mushiwan

By: Material type: TextTextPublisher: Kuantan, Pahang : UMP, 2018Copyright date: © 2018Description: xii, 56 pages : Illustrations (some color) ; 30 cm. + 1 CD-ROMContent type:
  • text
  • text
Media type:
  • unmediated
  • computer
Carrier type:
  • volume
  • computer disc
ISBN:
  • THE0008217(Local)
Subject(s): Dissertation note: Project Paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang – 2018 Abstract: This study concentrated on deciding potential of Bera Lake water quality for alternative source of water supply. Water quality is an important reference for describing the physical, chemical, and biological properties of water classification into each class. A study was conducted on physical, chemical, and biological parameter of Bera Lake on 2018 that contain water bodies at two stations with two sampling in two months of February and April 2018. Physical parameters were temperature and total suspended solids. Then, chemical parameters were pH value, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), ammonia nitrogen, phosphorus and selected heavy metals such as zinc, copper, cadmium and lead. For biological parameter were Total Coliform and E. Coli. The water was classified based on Water Quality Index (WQI) and National Water Quality for Malaysia (NWQS). Based on WQI standard, classifications of water quality were based on type of class. After accomplishment the laboratory test, two stations in Bera Lake can being determined classified into class 2. Station 1 with 79.33 is for class 2, if use for water supply need conventional treatment. Station 2 with 79.24 also in class 2. If want to being as water supply the conventional treatment were needed. Overall, identifying water quality is important for differentiate suitable purpose of water body. It is very important for conserving and preserve source of surface water for water supply purposes in a future.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG Reference Reference FKASA .L93 2018 r Bc. (Browse shelf(Opens below)) Not for loan 0000126997
Final Year Report Final Year Report UMPLIB GAMBANG CD11918 (Browse shelf(Opens below)) Not for loan 0000126998

Faculty of Civil Engineering and Earth Resources

Project Paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang – 2018

Includes bibliographical references

This study concentrated on deciding potential of Bera Lake water quality for alternative source of water supply. Water quality is an important reference for describing the physical, chemical, and biological properties of water classification into each class. A study was conducted on physical, chemical, and biological parameter of Bera Lake on 2018 that contain water bodies at two stations with two sampling in two months of February and April 2018. Physical parameters were temperature and total suspended solids. Then, chemical parameters were pH value, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), ammonia nitrogen, phosphorus and selected heavy metals such as zinc, copper, cadmium and lead. For biological parameter were Total Coliform and E. Coli. The water was classified based on Water Quality Index (WQI) and National Water Quality for Malaysia (NWQS). Based on WQI standard, classifications of water quality were based on type of class. After accomplishment the laboratory test, two stations in Bera Lake can being determined classified into class 2. Station 1 with 79.33 is for class 2, if use for water supply need conventional treatment. Station 2 with 79.24 also in class 2. If want to being as water supply the conventional treatment were needed. Overall, identifying water quality is important for differentiate suitable purpose of water body. It is very important for conserving and preserve source of surface water for water supply purposes in a future.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us