MARC details
| 000 -LEADER |
| fixed length control field |
02821ntm a2200361 i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MY-KuUP |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20251125105952.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
| fixed length control field |
t||||fr|||| 000 0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
220315s2021 my a|||frm||| 000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
THE0009164(Local) |
| Qualifying information |
hardback |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
UMP |
| Language of cataloging |
eng |
| Transcribing agency |
UMP |
| Description conventions |
rda |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
FTKEE .H83 2021 r Thesis |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Wan Nur Huda Aqilah Alias |
| Relator term |
author. |
| 245 10 - TITLE STATEMENT |
| Title |
Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control / |
| Statement of responsibility, etc. |
Wan Nur Huda Aqilah Alias |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Kuantan, Pahang : |
| Name of producer, publisher, distributor, manufacturer |
UMP, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2021 |
| 264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Date of production, publication, distribution, manufacture, or copyright notice |
© 2021 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xv, 91 pages : |
| Other physical details |
illustrations (some color) ; |
| Dimensions |
30 cm. + |
| Accompanying material |
1 CD ROM |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 336 ## - CONTENT TYPE |
| Content type term |
text |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Media type term |
unmediated |
| Source |
rdamedia |
| 337 ## - MEDIA TYPE |
| Media type term |
rdamedia |
| Source |
computer |
| 338 ## - CARRIER TYPE |
| Carrier type term |
volume |
| Source |
rdacarrier |
| 338 ## - CARRIER TYPE |
| Carrier type term |
computer disc |
| Source |
rdacarrier |
| 347 ## - DIGITAL FILE CHARACTERISTICS |
| File type |
text file |
| Encoding format |
PDF |
| Source |
rda |
| 500 ## - GENERAL NOTE |
| General note |
Faculty of Electrical & Electronics Engineering |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (Master of Science) -- Universiti Malaysia Pahang – 2021 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
The advancement of technology and the increase in population have increased the demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean and sustained power in vast quantities from sustainable energy. Recently, PV systems are frequently used owing to its light and easy-to-install characteristics. Although it was proven auspicious, faults can happen on the grid side of a grid-connected PV system, causing overshoot DC voltage and overcurrent. Thus, stressing the electrical component, lessening the system’s power quality and inverter’s trip. Therefore, many FRT strategies have been introduced to overcome these issues. This thesis proposed a new approach to alleviate this matter by controlling zero switching state of NPC inverter while injecting reactive current to the grid. First, the development of a two-stage grid-connected PV system was stated and the effects of grid faults were deliberated. Some conventional FRT strategies employed in the grid-connected PV system were studied. Furthermore, the efficiency of the scheme was verified by comparing it with a conventional method using DC chopper. The results showed the proposed method could lessen the overshoot DC voltage and injecting reactive current to the grid. Also, the results shown were similar to those of the conventional method. |
| 610 20 - SUBJECT ADDED ENTRY--CORPORATE NAME |
| Corporate name or jurisdiction name as entry element |
Faculty of Electrical & Electronics Engineering Technology |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Universities and colleges |
| General subdivision |
Dissertations |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Theses |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Thesis |