Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control / Wan Nur Huda Aqilah Alias

By: Material type: TextTextPublisher: Kuantan, Pahang : UMP, 2021Copyright date: © 2021Description: xv, 91 pages : illustrations (some color) ; 30 cm. + 1 CD ROMContent type:
  • text
  • text
Media type:
  • unmediated
  • rdamedia
Carrier type:
  • volume
  • computer disc
ISBN:
  • THE0009164(Local)
Subject(s): Dissertation note: Thesis (Master of Science) -- Universiti Malaysia Pahang – 2021 Abstract: The advancement of technology and the increase in population have increased the demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean and sustained power in vast quantities from sustainable energy. Recently, PV systems are frequently used owing to its light and easy-to-install characteristics. Although it was proven auspicious, faults can happen on the grid side of a grid-connected PV system, causing overshoot DC voltage and overcurrent. Thus, stressing the electrical component, lessening the system’s power quality and inverter’s trip. Therefore, many FRT strategies have been introduced to overcome these issues. This thesis proposed a new approach to alleviate this matter by controlling zero switching state of NPC inverter while injecting reactive current to the grid. First, the development of a two-stage grid-connected PV system was stated and the effects of grid faults were deliberated. Some conventional FRT strategies employed in the grid-connected PV system were studied. Furthermore, the efficiency of the scheme was verified by comparing it with a conventional method using DC chopper. The results showed the proposed method could lessen the overshoot DC voltage and injecting reactive current to the grid. Also, the results shown were similar to those of the conventional method.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Copy number Status Date due Barcode
Thesis Thesis UMPLIB PEKAN Reference Reference CD12928 (Browse shelf(Opens below)) 1 Not for loan T000001518
Thesis Thesis UMPLIB PEKAN Reference Reference FTKEE .H83 2021 r Thesis (Browse shelf(Opens below)) 1 Not for loan T000001517

Faculty of Electrical & Electronics Engineering

Thesis (Master of Science) -- Universiti Malaysia Pahang – 2021

Includes bibliographical references

The advancement of technology and the increase in population have increased the demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean and sustained power in vast quantities from sustainable energy. Recently, PV systems are frequently used owing to its light and easy-to-install characteristics. Although it was proven auspicious, faults can happen on the grid side of a grid-connected PV system, causing overshoot DC voltage and overcurrent. Thus, stressing the electrical component, lessening the system’s power quality and inverter’s trip. Therefore, many FRT strategies have been introduced to overcome these issues. This thesis proposed a new approach to alleviate this matter by controlling zero switching state of NPC inverter while injecting reactive current to the grid. First, the development of a two-stage grid-connected PV system was stated and the effects of grid faults were deliberated. Some conventional FRT strategies employed in the grid-connected PV system were studied. Furthermore, the efficiency of the scheme was verified by comparing it with a conventional method using DC chopper. The results showed the proposed method could lessen the overshoot DC voltage and injecting reactive current to the grid. Also, the results shown were similar to those of the conventional method.