A comparative study on milk protein separation using different technique / Wan Nurfarah Binti Wan Ali

By: Material type: TextTextPublication details: Kuantan : UMP, 2009Description: 54 p. : ill. ; 30 cm. + 1 computer discISBN:
  • THE0004537(Local)
Other title:
  • Comparative study on milk protein separation using different technique [electronic resource]
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2009 Abstract: Fractionation of full cream milk protein using two protein separation techniques which are crossflow filtration and conventional method was examined. Two membrane of MWCO of 10 and 50 kDa of polyethersulfone material were used to determine the efficiency of the process for crossflow filtration and filter paper were used for conventional method. The performance of crossflow filtration was determined under various processing conditions that include the transmembrane pressure across the membrane and the concentrations of milk sample from permeate. Among the membrane pore sizes tested, it was found that the 10 kDa MWCO membrane cassette can collected more protein compare with 50 kDa MWCO membrane cassette and conventional method. Permeate flux was primarily affected by pump speed and transmembrane pressure. The optimal operating conditions for this separation were transmembrane pressure of 15 psi for 10 kDa MWCO membrane. From the experiment, it showed that the permeate flux increased by increasing the time of operation, and transmembrane pressure. The high of transmembrane pressure can affect the process of protein separation because some fouling occurred at the membrane.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TP248.65.P76 W58 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042799
Final Year Report Final Year Report UMPLIB GAMBANG CD 3927 | TP248.65.P76 W58 2009 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000042800

Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2009

Fractionation of full cream milk protein using two protein separation techniques which are crossflow filtration and conventional method was examined. Two membrane of MWCO of 10 and 50 kDa of polyethersulfone material were used to determine the efficiency of the process for crossflow filtration and filter paper were used for conventional method. The performance of crossflow filtration was determined under various processing conditions that include the transmembrane pressure across the membrane and the concentrations of milk sample from permeate. Among the membrane pore sizes tested, it was found that the 10 kDa MWCO membrane cassette can collected more protein compare with 50 kDa MWCO membrane cassette and conventional method. Permeate flux was primarily affected by pump speed and transmembrane pressure. The optimal operating conditions for this separation were transmembrane pressure of 15 psi for 10 kDa MWCO membrane. From the experiment, it showed that the permeate flux increased by increasing the time of operation, and transmembrane pressure. The high of transmembrane pressure can affect the process of protein separation because some fouling occurred at the membrane.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur